搜索结果: 1-6 共查到“凹凸棒石 Analytical Electron Microscopy”相关记录6条 . 查询时间(0.098 秒)
Pedogenic Smectites in Podzols from Central Finland: An Analytical Electron Microscopy Study
Analytical Electron Microscopy Finland High-Resolution Transmission Electron Microscopy Podzols Smectites
2011/12/6
Abstract: Transmission electron microscopy (TEM) including high-resolution transmission electron microscopy (HRTEM) and analytical electron microscopy (AEM) were used to study the fine clay fraction (...
Direct Imaging of Zirconia Pillars in Montmorillonite by Analytical Electron Microscopy
Clays Electron Energy-Loss Spectroscopy Elemental Mapping Energy-Filtered Imaging Image Analysis Materials Characterization
2011/12/7
Abstract: Analytical electron microscopy was used to confirm the location of pillars of zirconia in pillared montmorillonite. Data show that the pillared clay is of “high” quality, with surface areas ...
Analytical Electron Microscopy in Clays and Other Phyllosilicates: Loss of Elements from a 90-nm Stationary Beam of 300-keV Electrons
Analytical Electron Microscopy Clay Minerals Diffusion Element Loss Low Temperature Phyllosilicates Sputtering Stationary Beam
2011/12/8
Abstract: Diffusion of alkali and low-atomic-number elements during the microbeam analysis of some silicates by analytical electron microscopy (AEM) has been known for some time. Our repeated analyses...
Analytical electron microscopy of nanometer-scale hornblende lamellae: Low-temperature exsolution in cummingtonite
Analytical electron microscopy nanometer-scale hornblende lamellae: Low-temperature cummingtonite
2012/4/6
Compositionalpro?lesacrosshostareasweremeasuredtohelpinterprettheunexpected
chemistriesofthenanometer-scalediscs.Apro?leacrosstheprecipitate-freezonebetween
acoarsehornblendelamellaandagroupofnanome...
Analytical Electron Microscopy and the Problem of Potassium Diffusion
Adularia Analytical electron microscopy Diffusion Muscovite Potassium Transmission electron microscopy
2012/1/10
Diffusion of K during analytical electron microscopy (AEM) results in anomalously low count rates for this element. As the analysis area and specimen thickness decrease, count rates become disproporti...
Transmission and Analytical Electron Microscopy of the Smectite-to-Illite Transition
Analytical electron microscopy Burial diagenesis Illite Interstratification Smectite Transmission electron microscopy
2012/1/11
The smectite to illite reaction was studied by transmission and analytical electron microscopy (TEM/AEM) in argillaceous sediments from depths of 1750, 2450, and 5500 m in a Gulf Coast well. Smectite ...