搜索结果: 1-14 共查到“理学 readout”相关记录14条 . 查询时间(0.124 秒)
Magnetically induced superresolution by center aperture detection (MSR-CAD) using pulsed and conventional dcshemes were applied to magneto-optical disks to quantitatively enaluate readout performances...
Deep sub electron noise readout in CCD systems using digital filtering techniques
CCD spectroscopy dark matter sub electron noise
2011/9/28
Scientific CCDs designed in thick high resistivity silicon (Si) are excellent detectors for astronomy, high energy and nuclear physics, and instrumentation. Many applications can benefit from CCDs ult...
A 1 mm Scintillating Fibre Tracker Readout by a Multi-anode Photomultiplier
Multi-anode Scintillating Fibre Tracker Readout
2011/9/7
This technical note describes a prototype particle tracking detector constructed with 1 mm plastic scintillating bres with a 64 channel Hamamatsu H8500
at-panel multi-anode photomultiplier readout....
Implementation of the readout system in the UFFO Slewing Mirror Telescope
UFFO, GRB, SMT, ICCD, Readout system, UBAT, Fast trigger
2011/9/14
The Ultra-Fast Flash Observatory (UFFO) is a new space-based experiment to observe Gamma-Ray Bursts (GRBs). GRBs are the most luminous electromagnetic events in the universe and occur randomly in any ...
Achieving sub-electron readout noise in Skipper CCDs
Skipper CCD, sub-electron noise reduction, Low energy X-ray detection
2011/9/13
The readout noise for Charge-Coupled Devices (CCDs) has been the main limitation when using these detectors for measuring small amplitude signals. A readout system for a new scientific, low noise CCD ...
Development of front-end readout electronics for silicon strip detectors
front-end readout electronics,system,ASIC, PXI-DAQ
2011/8/31
A front-end readout electronics system has been developed for silicon strip detectors. The system uses an application specific integrated circuit (ASIC) ATHED to realize multi-channel E&T measurement....
A High-resolution Scintillating Fiber Tracker With Silicon Photomultiplier Array Readout
High-resolution Scintillating Fiber Tracker Silicon Photomultiplier
2010/11/12
We present prototype modules for a tracking detector consisting of multiple layers of 0.25 mm diameter scintillating fibers that are read out by linear arrays of silicon photomultipliers. The module ...
A High-resolution Scintillating Fiber Tracker With Silicon Photomultiplier Array Readout
tracker scintillating ber silicon photomultiplier SiPM MPPC
2011/1/5
We present prototype modules for a tracking detector consisting of multiple layers of 0:25mm diameter scintillating bers that are read out by linear arrays of silicon photomultipliers.
Dispersive readout scheme for a Josephson phase qubit
Dispersive readout scheme Josephson phase qubit
2010/11/9
We present experimental results on a dispersive scheme for reading out a Josephson phase qubit. A capacitively shunted dc-SQUID is used as a nonlinear resonator which is inductively coupled to the qub...
An X-ray imaging device based on a GEM detector with delay-line readout
delay-line readout gas electron multiplier (GEM) X-ray imaging
2009/12/24
An X-ray imaging device based on a triple-GEM (Gas Electron Multiplier) detector, a fast delay-line circuit with 700 MHz cut-off frequency and two dimensional readout strips with 150 μm width on the t...
Design and test of a Multi-gap Resistive Plate Chamber with Long readout-strip (LMRPC)
LMRPC TOF gaseous detector
2009/8/14
A new kind (two end readout) of Multi-gap Resistive Plate Chamber with long readout-strip (LMRPC) is developed to be used at the large-area Muon Telescope Detector (MTD) at mid-rapidity at RHIC/STAR e...
Performance testing of a long-strip two-end readout multi-gap resistive plate chamber
MRPC timing resolution spacial resolution
2009/8/14
Multi-gap Resistive Plate Chamber (MRPC) is a new generation of gas detector with good timing and spacial resolution, whose technique is widely applied in some recent high energy (nuclear) physics exp...
Research on the delay-line readout for GEM detectors
GEM delay-line readout particle detector
2009/8/14
Based on the principles of transmission line and the output signal of GEM detector, a full simulation model of delay-line circuit has been described in this paper. The consistency of simulation result...
Study of readout and cross-talks for multi-strip RPC with PSpice simulation
RPC PSpice readout CT
2009/8/14
An electrical model for multi-strip resistive plate chamber (RPC) is presented, and a comparison between simulation results and test data is carried on. Based on the model, the influences of the RPC's...